Back to top

EcoSwing Superconducting Generator Proves Itself on the Test Bench

EcoSwing KryogenThe compact generator is attached to DyNaLab´s Stewart Platform in order to apply loads from the rotor site dynamically. (Courtesy of Fraunhofer-Gesellschaft zur Förderung der angewandten Forschung e.V.)

Compact design, low tower head mass, and good transportability: The generator developed in the EcoSwing research project, is to be used in the next generation of multi-megawatt turbines. To demonstrate practical feasibility of the superconductive concept, a test campaign on Fraunhofer IWES’ nacelle test bench followed by a field test on a two-blade turbine in Denmark was conceived. This first part at IWES is now completed and the experts at Fraunhofer IWES can confirm that this concept showed good results due to the functionality of the overall system. The testing of this high-temperature superconducting generator presented the test engineers with numerous challenges that were successfully addressed with special adaptions.

Sometimes less really is more: 40 per cent less weight and smaller dimensions than a comparable permanent magnet synchronous generator – these EcoSwing features are only possible thanks to superconductivity. With this solution just a fraction of the magnetically active material is required to outperform the power density of conventional generators. Since superconductors have practically no electrical resistance, the size of the conductor cross-section can be drastically reduced. This is a highly promising property for the development of future turbine generations.

"As world first, we stepped up in applying superconducting technology with the ambitious project EcoSwing. In order to reduce uncertainties, new technology needs testing under realistic conditions. The DyNaLab provided the opportunity to test under definable conditions and gain reliable results," says Jesper Hansen, Senior Project Manager at Envision Energy.

The EcoSwing rotor is made up of two parts which are thermally decoupled by a vacuum chamber. The part responsible for the bearing and the mechanical connection of the generator rotor is operated at ambient temperatures; the electromagnetic part of the generator rotor is designed to operate at cryogenic temperatures. This places particular requirements on the test bench: The generator has to be cooled down to 30 K (that is about -240 °C) using a closed-cycle gas cooling. While this was the first time that such a cooling system has been operated at Fraunhofer IWES, it got confirmed that this type of cooling performed very reliably.

Within the framework of EcoSwing, Fraunhofer IWES designed the mechanical adaptations for connecting to the test bench and, in doing so, developed and integrated a highly accurate measurement system for recording the enormous torques:

“Due to the special drive train concept, the generator is subject to virtually no parasitic loads when in use in the turbine, thus this situation also had to be ensured on the test bench. To achieve this, the generator was installed and adjusted with highest levels of precision,” said Hans Kyling, IWES project leader for EcoSwing, explaining this unique challenge.

At the same time, a further prerequisite was also all-important: The generator had to be fixed in such a way as to allow evasive action when subject to a nominal load. The specific adaptation prevented constraining forces from acting on the test object and influencing the test data.

The test results are confirmation of the successful validation and excellent functionality of the system. The project partners are now looking forward to the field campaign with a 3.6 MW test turbine from Envision in Denmark. The generator with a diameter of just 4 m will be transported there by ship.

The project runs until end of Feb. 2019. The next step, focusing on commercial wind applications, is already being planned by the project partners.

More info on https://ecoswing.eu

References

[1]

Fraunhofer-Gesellschaft zur Förderung der angewandten Forschung e.V. Press release - EcoSwing Superconducting Generator Proves Itself on the Test Bench. URL: https://www.iwes.fraunhofer.de/en/press---media/ecoswing-superconducting-generat.... [Date Accessed: 01/10/2018].

Technology

16 Jan | Design Certificate of 160m Nabralift Self-Erecting Tower awarded by DNV-GL

DNV-GL has awarded Nabrawind with the Design Evaluation Conformity Statement for the first Nabralift Self-Erecting tower design, that was prototyped last summer in Eslava (Spain), with a total hub height of 160m.

Technology

16 Jan | GE's Haliade-X 12 MW prototype to be installed in Rotterdam

  • Agreement signed with Future Wind includes five years of testing and 15 years of service
  • Installation of Haliade-X 12 MW will take place during summer 2019

Technology

15 Jan | Ingeteam is participating in the project for the first offshore wind turbine in Spain

Ingeteam is participating in the first bottom-fixed foundation offshore wind turbine prototype to be installed in Spain and the first of its kind in southern Europe.

Technology

09 Jan | Maxwell Technologies Launches New 3-Volt (3.0V) Platform for Full Range of Market Applications

Innovative Ultracapacitor Cells Offer Highest Energy and Power Yet in Company's Portfolio

06 May | Bearing Test Bench Now Fully Functional

Over the past months, the first blade bearings have been tested in Hamburg on the new BEAT 6.1 test bench using a highly simplified yet customary setup.

09 Apr | How accurately can system test benches simulate field tests?

During a two-month test campaign, the scientists from Fraunhofer IWES will be determining in the Dynamic Nacelle Testing Laboratory (DyNaLab) how the nacelle of a 3 MW wind turbine from ENERCON reacts to grid faults.

27 Feb | Large bearing test bench starts continuous operation

Fraunhofer´s test bench for rotor blade bearings of up to 6.5 meters in diameter has been successfully commissioned at the institute’s Hamburg facility, paving the way for automated continuous operation.

Technology

07 Jan | Better Protection for Power Converters

Power converters are among the most frequently failing components of wind turbines and are thus associated with high costs and long downtimes.